Heating Load Calculator

Heating load for a home from floor area, insulation standard and design temperatures.

Enter values

Results update as you type.

Result

Heating load

11.4 kW

Space heating
8.4 kW
Hot water allowance
3 kW
In BTU/hour
38,898
Design temperature difference
23 K
Load per m²
70 W/m²
Suggested boiler size
12 kW

A sizing estimate — a full room-by-room heat loss survey is needed before specifying equipment.

About the Heating Load Calculator

Heating load for a home from floor area, insulation standard and design temperatures.

Also known as: boiler size calculator, heat pump sizing, heating kw calculator, radiator sizing.

How to use this calculator

  1. Enter total floor area, average ceiling height, building standard, indoor design temperature and the other fields.
  2. The result updates instantly as you type — press Calculate (or Enter) at any time.
  3. Review the breakdown shown under the main result.
  4. Use Copy result or Share to save the answer or send a link with your inputs.

Formula

load = area × specific load × ΔT ÷ design ΔT + hot water

Worked example

Using the values pre-filled in the calculator above:

  • Total floor area = 120 m²
  • Average ceiling height = 2.4 m
  • Building standard: Average (70 W/m²)
  • Indoor design temperature = 21 °C
  • Outdoor design temperature = -2 °C
  • Hot water allowance = 3 kW

the calculator returns:

  • Heating load: 11.4 kW
  • Space heating: 8.4 kW
  • Hot water allowance: 3 kW
  • In BTU/hour: 38,898